Mounted on wheeled cart with small side storage cabinet. Blowers, filters and controls are mounted below the work surface to lower the center of gravity
|
Mounted on a wheeled cart with an enclosed chemical storage area in the base cabinet
|
Provides wheelchair access to the workstation front. Control are mounted in a handheld remote box placed inside the workzone.
|
A basic workstation, mounted on wheeled cart.
|
Horizontal Inflow
|
Downflow exhaust, bottom
|
Upflow exhaust, top
|
Upflow exhaust, top
|
Upflow exhaust, top
|
Air sampling port
|
|
|||
Base cabinet
|
|
|
||
Dynamic filter chamber
|
|
|||
Hour counter
|
|
|||
Optional service fixtures, cup sink
|
||||
Push/Pull handle
|
|
|
||
Safety filter
|
|
|||
Storage compartment
|
|
|
||
Track and wheel filter insert/remove function
|
|
The EDU-MOBILE maintains a constant face velocity of 100 FPM in compliance
with USA and International standards for safety and performance. Contaminated
air is pulled through the Multiplex Filtration System where activated carbon adsorbs chemical vapors, returning clean air to the room.
Low height and low center of gravity for stability when moving.
A. The main filter is easy to replace; no tools required. The filter clamps tightly against the filter gasket to prevent filter bypass and to maintain filter integrity.
EDU-MOBILE, EDU-M shown with Multiplex Filtration System.
|
The EDU-CLASSIC maintains a constant face velocity of 100 FPM in compliance with USA and International standards for safety and performance. Contaminated air is pulled through the Multiplex Filtration System where activated carbon adsorbs chemical vapors, returning clean air to the room.
A. The main filter is easy to replace; no tools required. The filter clamps tightly against the filter gasket to prevent filter bypass and to maintain filter integrity.
EDU-CLASSIC, P15-ENCB shown with Multiplex Filtration System.
|
The EDU-ADA maintains a constant face velocity of 100 FPM in compliance with USA and International standards for safety and performance. Contaminated air is pulled through the
Multiplex Filtration System where activated carbon adsorbs chemical vapors, returning clean air to the room.
A. The main filter is easy to replace; no tools required. The filter clamps tightly against the filter gasket to prevent filter bypass and to maintain filter integrity.
EDU-ADA, P10XL-CART-RC-P shown with Multiplex Filtration System.
|
The EDU-JUNIOR maintains a constant face velocity of 100 FPM in compliance with USA and International standards for safety and performance. Contaminated air is pulled through the Multiplex Filtration System where activated carbon adsorbs chemical vapors, returning clean air to the room.
A. The main filter is easy to replace; no tools required. The filter clamps tightly against the filter gasket to prevent filter bypass and to maintain filter integrity.
EDU-JUNIOR, P5-24XT-CART shown with Multiplex Filtration System.
|
The EDU-MOBILE is mounted
on a wheeled cart with a small side storage compartment. Blowers, filters and controls are mounted beneath the work surface to lower the center of gravity and simplify moving from room to room.
EDU-MOBILE, EDU-M
|
Model
|
Dimensions
|
Weight (lbs/Kg)
|
|||
|
Internal Height
|
External
(W x D x H)
|
Shipping
(W x D x H)
|
Net
|
Ship
|
EDU-M
|
31.5"
800 mm
|
39.5" x 28.5" x 77.5"
1003 x 724 x 1968 mm
|
40" x 50" x 80"
1016 x 1272 x 2032 mm
|
270 / 123
|
320 / 145
|
The EDU-CLASSIC has horizontal inflow with top mounted filters and exhaust. This model is mounted on a wheeled cart with an enclosed
chemical storage area in the cabinet base.
EDU-CLASSIC, P15-ENCB
|
Model
|
Dimensions
|
Weight (lbs/Kg)
|
|||
|
Internal Height
|
External
(W x D x H)
|
Shipping
(W x D x H)
|
Net
|
Ship
|
P15-ENCB
|
31.5"
800 mm
|
39.5" x 28.5" x 83.5"
1003 x 724 x 2121 mm
|
40" x 50" x 80"
1016 x 1272 x 2032 mm
|
270 / 123
|
320 / 145
|
The EDU-ADA permits wheelchair access to the workstation. Controls are mounted in a handheld remote box that can be placed adjacent to or inside the work area.
Model EDU-ADA on mounting stand. Stand can be fitted with optional adjustable height legs (shown) or optional mobile locking casters.
|
Model
|
Dimensions
|
Weight (lbs/Kg)
|
|||
|
Internal Height
|
External
(W x D x H)
|
Shipping
(W x D x H)
|
Net
|
Ship
|
P10XL-CART-RC-P
|
31.5"
800 mm
|
39.5" x 28.5" x 83.5"
1003 x 724 x 2121 mm
|
40" x 40" x 80"
1016 x 1016 x 2032 mm
|
234 / 107
|
284 / 129
|
The EDU-JUNIOR is a basic
workstation mounted on a wheeled cart.
EDU-JUNIOR, P5-24XT-CART
|
Model
|
Dimensions
|
Weight (lbs/Kg)
|
|||
|
Internal Height
|
External
(W x D x H)
|
Shipping
(W x D x H)
|
Net
|
Ship
|
P5-24XT-CART
|
24"
610 mm
|
24" x 27" x 70"
610 x 686 x 1778 mm
|
40" x 40" x 80"
1016 x 1016 x 2032 mm
|
176 / 80
|
225 / 102
|
Inorganic Fumes
Aluminum Chloride and Bromide
Ammonia
Ammonium Chloride Fumes
Bromine
Chlorine
Chromium (V1) Dichloride Dioxide
Chromyl Chloride
Hydrogen Acid Vapor
Hydrogen Sulphide
Iodine
Iodine Chlorides
Lead
Lead Bromide
Mercury and its Compounds
Nitric Acid Vapor
Nitrogen Oxides (Acidic)
Phosphine
Phosphorus Chlorides and Bromides
Phosphorous Oxides
Silicon Tetrachloride
Sulphur Chloride
Sulphur Dioxide
Thionyl Chloride
Tin (IV) Chloride
Titanium Tetrachloride
Zinc Chloride Fumes
|
Organic Fumes
Acid Amides
Acid Anhydrides
Acid Chlorides
Acidic Nitrogen Oxide
Alcohols
Aldehydes
Aliphatic Amines and their Salts
Aliphatic Hydrocarbons
Aromatic Amines and Aromatic Hydrocarbons
Aromatic Nitro Compounds
Carboxylic Acids
Esters
Ethers
Ketones
Nitriles
Organo Halogens
Phenols
Pyridine
Dust and Particles
Dyes
Enzymes
Smoke
WarningExclusions
This filter will not adsorb hydrogen, carbon monoxide, nitrous oxide or methane.
|
Quality Management Systems
|
ISO 9001
|
Chemical Fume Containment
|
ANSI/ASHRAE 110-1995
SafeBridge® Performance Verification (VE)
|
Carbon Filter Efficiency
|
BS 7989:2001
SEFA Standard 9
AFNOR NF X 15-211
|
Biological Safety Filter Efficiency
HEPA and ULPA
|
IEST-RP-CC-0034.2
IEST-RP-CC007.1
IEST-RP-CC001-4
EN 1822
|
Electrical Safety
|
UL-C-61010-1
CE Mark
ROHS Exempt under EEE Category 9
|
Product Design
|
ANSI Z 9.5-2003
ANSI Z 9.7-1998
|
OSHA, Occupational Safety and Health Administration
|
OSHA Standard - 29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. All Air Science® products meet this definition.
|
Environment
|
ISO 14001
Energy Star Partner
|
Education (UK)
|
CLEAPPS® Instruction Approved (EDU-M)
|
EDU Model
|
EDU-Mobile
|
EDU-Classic
|
EDU-ADA
|
EDU-Junior
|
Airflow CFM
|
220
|
220
|
145
|
135
|
Face Velocity FPM
|
100
|
100
|
100
|
100
|
Lighting
|
Compact fluorescent lamp.
|
|||
Construction
|
White epoxy steel frame and head unit, Clear sides and back panel.
|
|||
Blower
|
ebmpapst centrifugal fan.
|
|||
Electrical
|
120V, AC, 60Hz or 230V, AC, 50Hz voltages available. Specify when ordering. Other voltage options available.
|
|||
Electrical Switches
|
Main On/Off
|
|||
Monitoring
|
Low airflow alarm, standard.
|
Pre-Filter
|
Electrostatic, 1 lb / 0.45 kg, nominal.
|
|||
Main Filter
|
22 lbs / 9.6 kg
|
11 lbs / 5 kg
|
EDU Model
|
|
EDU-MOBILE
|
EDU-CLASSIC
|
EDU-ADA
|
EDU-JUNIOR
|
Filter Saturation Alarm*
|
An electronic gas sensor emits audio and visual alerts when the main filter needs to be changed.
|
FSA
|
FSA
|
FSA
|
FSA
|
Monitair® Controller*
|
Microprocessor controller monitors cabinet operating parameters, airflow, containment, and filter condition; emits audio and visual alerts if conditions become unsafe.
|
MON-P
|
MON-P
|
MON-P
|
N/A
|
Polypropylene Construction*
|
Cabinets are available in all polypropylene construction. Contact Air Science® for information.
|
EDU-M-PP
|
P15-ENCB-PP
|
P10XL-CART-RC-P-PP
|
P5-24XT-CART-PP
|
Duplex Electrical Outlet*
|
Two NEMA 14-20R receptacles with ground fault interrupter. 110V service standard; international fixtures available.
|
AS-GFI
|
AS-GFI
|
AS-GFI
|
AS-GFI
|
Service Fitting
|
Cabinets can be fitted with service fixtures such as petcocks, faucets or valves.
|
SF-X. Specify service fitting type (faucet, valve, petcock) and location when ordering.
|
|||
Cup Sink, Mounts into Tray*
|
Cup sink is fitted into the base tray.
|
SINK-P
|
SINK-P
|
SINK-P
|
SINK-P
|