Call us at 732 292-1994 or 800 867-6690 | Email us at triadscientific@gmail.com | Visite us on
PLANET BEST
Lab Instrumentation
Lab Equipment
Lab Furniture
| ||
|
Part of the trusted Safefume line of automatic fuming chambers, the Safefume 360 is used to develop latent prints from non-porous surfaces in a controlled and safe environment. The Safefume 360 is available in several sizes, starting at small bench top units through to larger walk-in chambers.
Applications
THE AIR SCIENCE PERFORMANCE ADVANTAGE
Safefume 360 automatic cyanoacrylate fuming chambers include features expressed through sound design and certified quality construction. Accessories add functional performance to meet specific applications.
Professional Quality
Safefume 360 automatic cyanoacrylate fuming chambers comply with current technical and safety regulations.
Multiplex Filtration
The Air Science Multiplex Filter offers high performance and safety.
Industrial Components
The cabinet frame and work surfaces are durable and chemically resistant.
Reliability
Internal systems are isolated from fumes, extending product life.
Easy to Install
Air Science ductless chambers are self-contained. Set-up, operation and ï¬lter maintenance are straightforward.
SAFEFUME 360 FEATURES AND BENEFITS:
The Air Science Safefume 360 automatic cyanoacrylate fuming chambers safely and automatically develop latent fingerprints on most non-porous surfaces using the proven technique of exposure to ethyl cyanoacrylate vapor. Evidence is positioned in the chamber with a flexible system of hanging rods and shelves. A fully automatic system controls and monitors the process.
PRODUCT FEATURES:
A. Dynamic Filtration Chamber: The dynamic filter chamber prevents leakage of contaminated air by maintaining partial vacuum in the filter plenum.
B. Control Panel: The microprocessor control panel manages the Printbuster Pro operating sequence with control, oversight and display of all processing functions. The LCD display works with a touchpad data entry keypad to establish all operating parameters.
C. Doors: Tempered glass, keyed doors with aluminum frame and tamper-proof seal provide improved security, stability and ease of cleaning. Scratch-resistant glass for lasting optimum visibility.
D. Fan: High velocity sparkless and brushless centrifugal fan.
E. Hanging Rods: Removable and adjustable stainless steel hanging rods for proper orientation of evidence.
F. Water Nebulizer/Humidifier: Water nebulizer to elevate humidity in chamber.
G. Hot Plate Accelerator: Hot plate to polymerize ethyl cyanoacrylate. Optional programmable hot plate (0-400 ºC) also available.
H. Optional UV Lamp: Activated ultraviolet light provides secondary disinfection of the interior between cases to prevent cross-contamination, ensuring integrity of the samples for DNA testing.
I. Uninterruptable Power Supply: Backup power supply to support all systems for one complete machine cycle in the event of power failure.
Standards Compliant: Performance specifications and construction meet or exceed OSHA, ANSI and relevant international standards to assure operator safety.
Construction: Models are available in either polypropylene and epoxy-coated steel or aluminum frame with plastic wall construction. Locking doors are tempered glass with tamper-proof seal and aluminum frame. See selection chart for specifications and dimensions. Available in 110V, 60Hz single phase electrical supply (other voltages available on request).
Internal Chamber Cleansing: The Internal Chamber Cleansing feature automatically activates to eliminate contamination and remove the harmful vapor from the unit. This process is especially important if the unit is used infrequently or only during certain periods of high evidence volume.
The microprocessor control panel manages the
Printbuster Pro operating sequence with control,
oversight and display of all processing functions.
The LCD display works with a touchpad data entry
keypad to establish all operating parameters. |
|
|
|
AIR SCIENCE® PRINTBUSTER PRO LCD INTERFACE TECHNOLOGY
Printbuster Pro is the industrys first use of touch-screen technology offering a simple, easy-to-use solution delivering repeatable results every time. The automatic latent fingerprint development cycle manages the following:
|
|
|
A high volume, stand alone, fingerprinting chamber designed for processing large amounts of evidence on a regular basis. Large items such as automobile doors, tires, bicycles and others are easily processed in this unit. This model offers the same functionality as our smaller versions including the Printbuster Pro control system.
The Multiplex filter configuration permits a customized combination of filter media for a broad range of chemical families and biological agents if required. EFT Filtration Technology broadens the Air Science application for ductless fume hoods.
Click here for more information on Multiplex Filtration Technology.
Model
|
Dimensions
|
Weight (lbs/Kg)
|
|||
|
Internal
Height
|
External
(W x D x H)
|
Shipping
(W x D x H)
|
Net
|
Ship
|
ARV-24
|
27.5"
699 mm |
24" x 25" x 30"
610 x 635 x 762 mm |
30" x 34" x 38"
762 x 864 x 965 mm |
83 / 38
|
125 / 57
|
ARV-33T
|
50"
1270 mm |
33" x 34" x 70"
838 x 864 x 1778 mm |
39" x 43" x 78"
991 x 1092 x 1981 mm |
291 / 132
|
331 / 150
|
ARV-60T
|
82"
2083 mm |
60" x 29" x 87"
1524 x 737 x 2210 mm |
66" x 44" x 95"
1676 x 1118 x 2413 mm |
390 / 177
|
449 / 204
|
ARV-72XL
|
80"
2032 mm |
72" x 48" x 86"
1829 x 1219 x 2184 mm |
80" x 54" x 95"
2032 x 1372 x 2413 mm |
825 / 374
|
968 / 439
|
Specifications are subject to change without notice.
Safefume 360 Models |
ARV-24
|
ARV-33T
|
ARV-60T
|
ARV-72XL
|
Construction
|
Aluminum frame with tempered glass and door with key locks and tamper-proof seals. Hanging rail.
|
|||
Blower
|
ebmpapst centrifugal fan.
|
|||
Electrical Switches
|
Main On/Off
|
|||
Monitoring
|
Complete monitoring of all functions. |
|||
Hanging Rods
|
1
|
2
|
2
|
2
|
Shelves
|
1
|
1
|
3
|
-
|
Pre-Filter
|
Electrostatic
|
Main Filter
|
Carbon
|
Safefume 360 Models |
|
ARV-24
ARV-33T ARV-60T ARV-72XL |
DNA Decontamination
UV lamp*
|
A UV lamp is available for overnight decontamination of interior surfaces.
The UV kit includes a timer and door micro switch interlock. The UV operation
must comply with local codes and facility safety practices.
Contact your facility safety officer for details.
|
CA-UV
|
Automatic Lock-Out System
|
Safety supplement to standard key lock system. Automatic lock-out system is
interconnected to the main control system to prevent premature or unauthorized access to interior chamber.
|
EM-LOCK
|
Adjustable Temp Hot Plate
|
Allows programmable temperatures from 0-400 ºC for use of standard
and specialty cyanoacrylates.
|
ADJ-HP
|
Uninterruptable Power Supply
|
Capable of supporting all systems for one complete machine cycle
in the event of power failure.
|
UPS
|
Cleaning Kit
|
Complete kit for cleaning the chamber.
|
C-KIT
|
Evidence Baskets
|
Hanging wire baskets to place evidence.
|
EV-B
|
Quality Management Systems
|
ISO 9001
|
Chemical Fume Containment
|
ANSI/ASHRAE 110 1995
|
Carbon Filter Efficiency
|
BS 7989-2001
SEFA Standard 9
AFNOR NFX 15-211
|
Electrical Safety
|
UL-C-61616A
ROHS Exempt under EEE Category 9
|
Product Design
|
ANSI Z 9.5-2003
ANSI Z 9.7-1998
|
OSHA, Occupational Safety and Health Administration
|
OSHA Standard -29 CRF, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. All Air Science® products meet this definition.
|
Environment
|
ISO 14001 Energy Star Partner
|